Proceedings Vol. 23 (2017)
ENGINEERING MECHANICS 2017
May 15 – 18, 2017, Svratka, Czech Republic
Copyright © 2017 Brno University of Technology, Faculty of Mechanical Engineering, Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno
ISSN 1805-8248 (printed)
ISSN 1805-8256 (electronic)
list of papers scientific commitee
pages 378 - 381, full text
Corrosion of steel reinforcement is the major cause of deterioration of existing RC structures. Combined effects of moisture, temperature, and chlorides reduce the alkalinity of concrete and exacerbate the corrosion of steel reinforcement, especially for concrete structures subjected to aggressive environments, such as marine structures and bridges and parking garages exposed to de-icing salts. Glass fiber reinforcement polymer (GFRP) bars are suitable alternatives to steel bars in reinforced concrete applications if durability, electromagnetic transparency, or ease of demolition in temporary constructions is sought, that have to be demolished partially by tunnel boring machines (TBMs). The bond of GFRP reinforcement is different from steel reinforcing bars. This paper presents factors affecting the bond strength between GFRP reinforcement and concrete.
back to list of papers
Text and facts may be copied and used freely, but credit should be given to these Proceedings.
All papers were reviewed by members of the scientific committee.