pages 169 - 172, full text
This work presents investigations into tendons of human origin used for the reconstruction of ligaments in the knee joint. The scope of tests included a static tensile test using strength testing machine MTS Criterion Model 43 (MTS Systems, Eden Prairie, MN, USA). Samples of long peroneal muscle (peroneus longus) tendons and short peroneal muscle (peroneus brevis) tendons were subjected to testing. The main objective of the research was to determine mechanical properties of tendons after a prolonged period of storage, which lasted 9 years. The following mechanical properties of tendons were obtained: maximum breaking force Fmax , maximum stress σmax [MPa] and Young's modulus E [MPa].
back to list of papers
Ownership of copyright in original research articles remains with the Authors, and provided that, when reproducing parts of the contribution, the Authors acknowledge and/or reference the Proceedings, the Authors do not need to seek permission for re-use of their material.
All papers were reviewed by members of the scientific committee.